評(píng)價(jià)磁共振彌散加權(quán)成像在急性缺血性腦梗死的診斷效能
Toevaluate the diagnostic efficacyof diffusion-weighted magneticresonance imagingin acute ischemic cerebral infarctionLi Yu Cheng Guoyi.Imaging Department, Xinzheng Tianyou Hospitalof Traditional Chinese Medicine, Zhengzhou 451150,China
【Abstract】ObjectiveTo analyze the diagnostic eficacyof diffusion-weighted magnetic resonance imaging (DWI) inacute ischemiccerebral infarction.MethodsAtotalof97patientswith suspectedacute ischemiccerebral infarction who were treated inour hospital from January2O19to December 2O23were providedwith the CT examination andDWIscan.Thediagnostic efcacyofCTand DWIwascomparedand analyzed withtheresultsof cerebrovascularangiographyasthegoldstandard forthediagnosisofacute ischemiccerebral infarction.Theapparent brain tissue difusion coefficient (ADC)with acute ischemiccerebral infarction was compared with different clinical stages,beforeand after thrombolytic therapy,and with diferent prognoses.ResultsThediagnosticsensitivity and accuracy of DWI in acute ischemic cerebral infarction were higher than those of CT( P <0.05). The differences in diagnostic specificity,positive predictive value,and negative predictivevalue between the two diagnostic methods were not significant P>0.05 . The two groups were compared,ADC values of patients with hyperacute and acute cerebral infarction were higherthanthoseon theafected side,and ADCvalues of the healthy side were lower than those on the affected side in the subacute stage ( P <0.05).The brain tissue of ADC value of the affected side of the patients in thehyperacutestage was the lowest,followed by the acute stage,and the ADC valuein the brain tissue of the patients in the subacute stage was the highest ( P <0.05).The ADC value of acute ischemic cerebral infarction after thrombolytic therapy was higher than that before treatment ( P <0.05). The ADC value of brain tissue in the good prognosis group was higher than that of the poor prognosis group,andthe ADC value of brain tissue in diferent prognosis patients had statistical differences (P<0.05) .ConclusionDWI has high diagnostic efficacy in acute ischemiccerebral infarctionand can judge theclinical stage,and theeficacyof thrombolytic therapyandalso can be helpful to make prognosis,which is worthy of application.
【Key words】 Acuteischemic cerebral infarction;Difusion - weighted imaging;Diagnostic effectiveness;
急性缺血性腦梗死發(fā)病機(jī)制為局限性腦組織壞死,腦部突發(fā)性血液循環(huán)障礙影響腦組織正常供血,繼而使得腦組織出現(xiàn)缺氧,可引發(fā)殘疾或者死亡等嚴(yán)重不良結(jié)局[1,2]。(剩余6239字)
-
-
- 實(shí)用醫(yī)學(xué)影像雜志
- 2025年02期
- 基于 T2WI 和擴(kuò)散加權(quán)成像...
- 實(shí)時(shí)剪切波彈性成像技術(shù)對(duì)甲狀腺...
- 超聲表現(xiàn)對(duì)惡性甲狀腺結(jié)節(jié)的預(yù)測(cè)...
- 評(píng)價(jià)磁共振彌散加權(quán)成像在急性缺...
- 應(yīng)用三維相位對(duì)比磁共振靜脈成像...
- 超聲檢查聯(lián)合凝血指標(biāo)對(duì)老年下肢...
- 急性缺血性腦卒中患者頸動(dòng)脈斑塊...
- CT灌注成像聯(lián)合CT血管成像評(píng)...
- 雙能CT技術(shù)在高原地區(qū)高尿酸血...
- 單光子發(fā)射CT/CT對(duì)脊柱良惡...
- 磁共振成像在股骨和坐骨撞擊綜合...
- 多層螺旋CT征象對(duì)孤立性肺結(jié)節(jié)...
- 磁共振在胎兒腦組織結(jié)構(gòu)畸形和中...
- 基于自動(dòng)管電流調(diào)制技術(shù)不同定位...
- 1.5T磁共振成像彌散加權(quán)成像...
- 動(dòng)態(tài)增強(qiáng)磁共振成像聯(lián)合x線鉬靶...
- 多層螺旋CT引導(dǎo)下肺活檢穿刺在...
- 復(fù)發(fā)型視神經(jīng)脊髓炎早期診斷中磁...
- 慢性心力衰竭患者心臟超聲心功能...
- 胃血管球瘤CT特征初步探討...
- 頸動(dòng)脈斑塊彩色多普勒超聲聯(lián)合頭...
- 頭顱電子計(jì)算機(jī)斷層掃描血管造影...
- 多模態(tài)影像技術(shù)在冠狀動(dòng)脈微循環(huán)...